EN 10222-5 2017 Steel forgings Flanges for pressure purposes

EN 10222-5 Steel Forgings | Manufacturer & Supplier

We are a trusted manufacturer and exporter of EN 10222-5 steel forgings, supplying forged components for pressure purposes, boilers, nuclear plants, and high-temperature applications. The EN 10222-5 standard specifies the technical delivery conditions for austenitic and austenitic-ferritic (duplex) stainless steel forgings, widely used in industries that demand excellent corrosion resistance, strength, and durability.

Standard Overview

  • Standard: EN 10222-5
  • Title: Steel forgings for pressure purposes – Part 5: Martensitic, austenitic, and austenitic-ferritic stainless steels
  • Product Forms: Flanges, rings, discs, shafts, fittings, custom forged parts
  • Standard:EN 1092-1,ASME B16.5
  • Flange type:Weld neck flange,Blind Flange,Slip on Flange,Socket Weld flange
  • Bar type:Round bar,Rod,Hex bar
  • Delivery Condition: Solution annealed, quenched, tempered, or as specified

Main Material grade under EN 10222-5

Stainless steelsStandard
X2CrNi18-9W.Nr. 1.4307EN 10222-5
X2CrNiMo17-12-2W.Nr. 1.4406
X2CrNiMo17-13-2W.Nr. 1.4404
X2CrNiMoN22-5-3W.Nr. 1.4462
X2CrNiMo17-13-3W.Nr. 1.4429
X2CrNiMo25-7-4W.Nr. 1.4410
X3CrNiMo13-4W.Nr. 1.4313
X3CrNiMoN17-13-3W.Nr. 1.4436
X5CrNi18-10W.Nr. 1.4301
X5CrNiMo17-12-2W.Nr. 1.4401
X6CrNi18-11W.Nr. 1.4948
X6CrNiMoTi17-12-2W.Nr. 1.4571
X6CrNiNb18-10W.Nr. 1.4550
X6CrNiTi18-10W.Nr. 1.4541
X2CrNiMo18-14-3W.Nr. 1.4435
X2CrNiMo17-12-3W.Nr. 1.4432

EN 10222-5 Chemical composition (cast analysis) % by mass

Table 2 — Chemical composition (cast analysis) % by mass
Steel nameSteel numberCSi max.Mn max.P max.S max.CrMoNiNOthers
Martensitic steels
X3CrNiMo13 – 41.4313≤ 0,050,701,500,0400,01512,0 to 14,00,30 to 0,703,5 to 4,5≥ 0,020
Austenitic steels
X2CrNi18 – 91.4307≤ 0,0301,002,000,0450,015b17,5 to 19,58,0 to 10,5≤ 0,10
X2CrNi19 – 111.4306≤ 0,0301,002,000,0450,015b18,0 to 20,010,0 to 12,0≤ 0,10
X2CrNiN18 – 101.4311≤ 0,0301,002,000,0450,015b17,5 to 19,58,5 to 11,50,12 to 0,22
X5CrNi18 – 101.4301≤ 0,071,002,000,0450,015b17,5 to 19,58,0 to 10,5≤ 0,10
X6CrNiTi18 – 101.4541≤ 0,081,002,000,0450,015b17,0 to 19,09,0 to 12,0Ti: 5 x C to 0,70
X6CrNiNb18 – 101.455≤ 0,081,002,000,0450,015b17,0 to 19,09,0 to 12,0Nb: 10 x C to 1,00
X6CrNi18 – 101.49480,04 to 0,081,002,000,0350,015b17,0 to 19,08,0 to 11,0≤ 0,10
X6CrNiTiB18 – 101.49410,04 to 0,081,002,000,0350,015b17,0 to 19,09,0 to 12,0Ti: 5 x C to 0,80; B: 0,0015 to 0,0050
X7CrNiNb18 – 101.49120,04 to 0,101,002,000,0450,015b17,0 to 19,09,0 to 12,0Nb: 10 x C to 1,20
X2CrNiMo17 – 12 – 21.4404≤ 0,0301,002,000,0450,015b16,5 to 18,52,00 to 2,5010,0 to 13,0≤ 0,10
X2CrNiMo17 – 11 – 21.4406≤ 0,0301,002,000,0450,015b16,5 to 18,52,00 to 2,5010,0 to 12,50,12 to 0,22
X5CrNiMo17 – 12 – 21.4401≤ 0,071,002,000,0450,015b16,5 to 18,52,00 to 2,5010,0 to 13,0≤ 0,10
X6CrNiMoTi17 – 12 – 21.4571≤ 0,081,002,000,0450,015b16,5 to 18,52,00 to 2,5010,5 to 13,5Ti: 5 x C to 0,70
X2CrNiMo17 – 12 – 31.4432≤ 0,0301,002,000,0450,015b16,5 to 18,52,50 to 3,0010,5 to 13,0≤ 0,10
X2CrNiMo17 – 13 – 31.4429≤ 0,0301,002,000,0450,015b16,5 to 18,52,50 to 3,0011,0 to 14,00,12 to 0,22
X3CrNiMo17 – 13 – 31.4436≤ 0,051,002,000,0450,015b16,5 to 18,52,50 to 3,0010,5 to 13,0≤ 0,10
X2CrNiMo18 – 14 – 31.4435≤ 0,0301,002,000,0450,015b17,0 to 19,02,50 to 3,0012,5 to 15,0≤ 0,10
X3CrNiMoBN17 – 13 – 31.491≤ 0,040,752,000,0350,01516,0 to 18,02,00 to 3,0012,0 to 14,00,10 to 0,18B: 0,0015 to 0,0050
X2CrNiMo17 – 13 – 51.4439≤ 0,0301,002,000,0450,01516,5 to 18,54,00 to 5,0012,5 to 14,50,12 to 0,22
X1NiCrMoCu25 – 20 – 51.4539≤ 0,0200,702,000,0300,01019,0 to 21,04,00 to 5,0024,0 to 26,0≤ 0,15Cu: 1,20 to 2,00
X1CrNiMoCuN20 – 18 – 71.4547≤ 0,0200,701,000,0300,01019,5 to 20,56,00 to 7,0017,5 to 18,50,18 to 0,25Cu: 0,50 to 1,00
X1CrNiMoCu25 – 20 – 71.4529≤ 0,0200,501,000,0300,01019,0 to 21,06,00 to 7,0024,0 to 26,00,15 to 0,25Cu: 0,50 to 1,50
X2CrNiCu19 – 101.465≤ 0,0301,002,000,0450,01518,5 to 20,09,0 to 10,0≤ 0,08Cu ≤ 1,0
X3CrNiMo18 – 12 – 31.4449≤ 0,0351,002,000,0450,01517,0 to 18,22,25 to 2,7511,5 to 12,5≤ 0,08Cu ≤ 1,0
Austenitic – ferritic steels
X2CrNiN23 – 41.4362≤ 0,0301,002,000,0350,01522,0 to 24,00,10 to 0,603,5 to 5,50,05 to 0,20Cu: 0,10 to 0,60
X2CrNiMoN22 – 5 – 31.4462≤ 0,0301,002,000,0350,01521,0 to 23,02,50 to 3,54,5 to 6,50,10 to 0,22
X2CrNiMoCuN25 – 6 – 31.4507≤ 0,0300,702,000,0350,01524,0 to 26,03,00 to 4,06,0 to 8,00,20 to 0,30Cu: 1,00 to 2,50
X2CrNiMoN25 – 7 – 41.441≤ 0,0301,002,000,0350,01524,0 to 26,03,00 to 4,56,0 to 8,00,24 to 0,35
X2CrNiMoCuWN25 – 7 – 41.4501≤ 0,0301,001,000,0350,01524,0 to 26,03,00 to 4,06,0 to 8,00,20 to 0,30W: 0,50 to 1,00; Cu: 0,50 to 1,00

EN 10222-5 Mechanical properties at room temperature and for impact energy test at 20°C and –196°C

Mechanical properties at room temperature and for impact energy test at 20°C and –196°C
Steel gradeThickness of the ruling section tR0,2 % proof strength Rp0,21,0 % proof strength Rp1,0Tensile strength RmElongation after fracturea AImpact energya KV2Resistance to intergranular corrosionb
Steel nameSteel numberHeat treatmentmm max.MPa min.MPa min.MPa% min.J min.in the delivery conditionin the sensitized condition
ltr, tat 20 °C lat 20 °C tr, tat –196 °C tr
Martensitic steel
X3CrNiMo13-41.4313+QT or +T350550750 to 900171610080
X3CrNiMo13-41.4313+QT250650780 to 93017159070
Austenitic steels
X2CrNi18-91.4307+AT250200230500 to 70045351006060yesyes
X2CrNi19-111.4306+AT250180215460 to 68045351006060yesyes
X2CrNiN18-101.4311+AT250270305550 to 75045351006060yesyes
X5CrNi18-101.4301+AT250200230500 to 70045351006060yesno
X6CrNiTi18-101.4541+AT450200235510 to 71040301006060yesyes
X6CrNiNb18-101.455+AT450205240510 to 71040301006040yesyes
X6CrNi18-101.4948+AT250195230490 to 690453510060nono
X6CrNiTiB18-101.4941+AT450175210490 to 690403010060yesyes
X7CrNiNb18-101.4912+AT450205240510 to 71040301006040(yes)(yes)
X2CrNiMo17-12-21.4404+AT250190225490 to 69045351006060yesyes
X2CrNiMoN17-11-21.4406+AT160280315580 to 78045351006060yesyes
X5CrNiMo17-12-21.4401+AT250205240510 to 71045351006060yesno
X6CrNiMoTi17-12-21.4571+AT450210245510 to 71045351006060yesyes
X2CrNiMo17-12-31.4432+AT250190225490 to 69045351006060yesyes
X2CrNiMoN17-13-31.4429+AT160280315580 to 78045351006060yesyes
X3CrNiMo17-13-31.4436+AT250205240510 to 71045351006060yesno
X2CrNiMo18-14-31.4435+AT160200235520 to 67045351006060yesyes
X2CrNiMoN17-13-51.4439+AT160285315580 to 80040351006042
X1NiCrMoCu25-20-51.4539+AT160220250520 to 720353512090
X1CrNiMoCuN20-18-71.4547+AT160300340650 to 850403510060
X1CrNiMoCu25-20-71.4529+AT160300340650 to 85040351209080
X3CrNiMoBN17-13-31.491+AT75260300550 to 750454010060yesyes
X2CrNiCu19-101.465+AT450210245520 to 72045401006060(yes)(yes)
X3CrNiMo18-12-31.4449+AT450220255520 to 72045401006060(yes)(yes)
Austenitic-ferritic steels
X2CrNiN23-41.4362+AT160400600 to 830252012090yesyes
X2CrNiMoN22-5-31.4462+AT350450680 to 8803025200100yesyes
X2CrNiMoCuN25-6-31.4507+AT160500700 to 900252015090yesyes
X2CrNiMoN25-7-41.441+AT160500800 to 10003025200100yesyes
X2CrNiMoCuWN25-7-41.4501+AT160530

Applications of EN 10222-5 Forgings

  • Power generation (nuclear & thermal plants)
  • Petrochemical and refinery piping systems
  • Offshore oil & gas (subsea equipment, manifolds)
  • Chemical processing plants
  • Desalination plants & marine engineering
  • Boiler & pressure vessel construction

Why Choose Our EN 10222-5 Forgings?

Wide range of austenitic & duplex stainless grades

In-house forging, heat treatment & machining

Supplied with EN 10204 3.1 / 3.2 certificates

Third-party inspection by TÜV, BV, DNV, SGS, LR available

Download EN-10222-5 standard Specification